Thermal conductivity
All thermal conductivity derivatives are determined by perturbation.
Pure compound thermal conductivities are only available for use with internal mixture thermal conductivity routines. They cannot be used if no internal mixture routine is selected. For CAPE-OPEN version 1.1 external calculations, pure compound thermal conductivities are evaluated for each compound as mixture thermal conductivities with composition set to unity for that compound and zero for all other compounds.
Liquid Mixture Thermal Conductivity
Ideal
The ideal liquid thermal conductivity mixing:
DIPPR 9I
The DIPPR procedure 9I for liquid thermal conductivity mixing:
DIPPR 9H
The DIPPR procedure 9H for liquid thermal conductivity mixing:
where wi is the weight fraction of compound i.
High pressure correction
For all liquid thermal conductivity mixing models, a correction is applied when the pressure is larger than 35 bar:
This is DIPPR procedure 9G-1 where the mixture parameters are computed by the ideal mixing rules.
Pure compound liquid thermal conductivity
Temperature Correlation
The parameters for the temperature correlation for liquid thermal conductivity of pure compounds are available through TEA's PCD data files. If the reduced temperature exceeds 0.99, a value of 0.99 is used.
Pachaiyappan et al.
for straight chain hydrocarbons:
otherwise:
If the reduced temperature exceeds 0.99, a value of 0.99 is used. If the critical temperature is below 273.15 K, a value of 3 is used for b.
Sato-Riedel
Here, the reduced boiling temperature Tb,r is substituted by a default value of 0.65 if the normal boiling temperature is not available. If the reduced temperature exceeds 1, a value of 1 is used.
DIPPR procedure 9E
The Latini et al. procedure (DIPPR procedure 9E) for liquid thermal conductivity of pure compounds:
where parameters A*, α, β and γ depend on the class of the compound:
Family | A* | α | β | γ |
Saturated hydrocarbons | 0.0035 | 1.2 | 0.5 | 0.167 |
Olefins | 0.0361 | 1.2 | 1.0 | 0.167 |
Cycloparaffins | 0.0310 | 1.2 | 1.0 | 0.167 |
Aromatics | 0.0346 | 1.2 | 1.0 | 0.167 |
Alcohols, phenols | 0.00339 | 1.2 | 0.5 | 0.167 |
Acids (organic) | 0.00319 | 1.2 | 0.5 | 0.167 |
Ketones | 0.00383 | 1.2 | 0.5 | 0.167 |
Esters | 0.0415 | 1.2 | 1.0 | 0.167 |
Ethers | 0.0385 | 1.2 | 1.0 | 0.167 |
Refrigerants: | ||||
R20, R21, R22, R23 | 0.562 | 0.0 | 0.5 | -0.167 |
Others | 0.494 | 0.0 | 0.5 | -0.167 |
If the reduced temperature exceeds 0.99, a value of 0.99 is used.
Per compound
When selecting the Per Compound routine, the above methods can be selected on a per-compound basis in the compounds tab.
Vapor Mixture Thermal Conductivity
Ideal
The mixture vapour thermal conductivity is computed from the pure compound thermal conductivities as follows:
Kinetic theory
This is DIPPR procedure 9D:
where interaction parameters φij are computed from:
Note that the compound viscosities are required for this evaluation.
High pressure correction
If the system pressure is larger than 1 atmosphere a correction is applied according to DIPPR procedure 9C-1. Mixture parameters are computed using the ideal mixing rules. Critical and reduced densities are computed from:
If the reduced density is below 0.5, then
else, if the reduced density is below 2, then
otherwise
The high pressure thermal conductivity correction is then calculated from:
which must be added to the calculated thermal conductivity for low pressure.
Pure compound vapor thermal conductivity
Temperature Correlation
The parameters for the temperature correlation for vapor thermal conductivity of pure compounds are available through TEA's PCD data files.
DIPPR procedure 9B-3
DIPPR procedure 9B-3 for pure compound thermal conductivity:
DIPPR procedure 9B-2
DIPPR procedure 9B-2 for pure compound thermal conductivity:
This method is recommended for linear molecules.
DIPPR procedure 9B-1
DIPPR procedure 9B-1 for pure compound thermal conductivity:
This method is suitable for mono-atomic gases only.
Misic-Thodos 2
This method is used for methane and cyclic compounds.
This method should be used when Tr < 1. A warning is produced if this is not the case.
Misic-Thodos 1
This method is used for all compounds but methane and cyclic compounds.
Per compound